Dell POWEREDGE R610 User Manual
Page 24

24
About Your System
To resolve the problem and remove the LCD message, refer to the corrective
actions in the following table.
NOTE:
The following LCD status messages are displayed in the Simple format. See
“Setup Menu“to select the format in which the messages are displayed.
Table 1-1. LCD Status Messages
Code
Text
Cause
Corrective Actions
E1000
Failsafe
voltage
error.
Contact
support.
Check the system event log
for critical failure events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
If the problem persists,
see "Getting Help."
E1114
Ambient Temp
exceeds
allowed
range.
Ambient temperature has a
reached a point outside of
the allowed range.
Problems."
E1116
Memory
disabled,
temp above
range. Power
cycle AC.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
Problems."
If the problem persists,
see "Getting Help."
E1210
Motherboard
battery
failure.
Check
battery.
CMOS battery is missing or
the voltage is outside of the
allowable range.
E1211
RAID
Controller
battery
failure.
Check
battery.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See "Installing