beautypg.com

Dell POWEREDGE R610 User Manual

Page 52

background image

52

About Your System

Warning: A fatal

error has caused

system reset!

Please check the

system event log!

A fatal system error occurred

and caused the system to

reboot.

Check the SEL for

information that was logged

during the error. See the

applicable troubleshooting

section in "Troubleshooting

Your System" for any faulty

components specified in the

SEL.

Warning! Control

panel is not

installed

The control panel is not

installed, or has a faulty cable

connection.

Install the control panel, or

check the cable connections

between the display module,

the control panel board, and

the system board. See

"Installing the Control Panel

Display Module."

Warning! No micro

code update

loaded for

processor

n

Micro code update failed.

Update the BIOS firmware.

See "Getting Help."

Warning! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Warning!

Performance

degraded. CPU and

memory set to

minimum

frequencies to

meet PSU wattage.

System will

reboot.

The system configuration of

processor(s), memory

modules, and expansion

cards may not be supported

by the power supplies.

If any system components

were just upgraded, return

the system to the previous

configuration. If the system

boots without this warning,

then the replaced

component(s) are not

supported with this power

supply. If Energy Smart

power supplies are installed,

replace them with the High

Output power supplies to use

the components. See "Power

Supplies."

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions