beautypg.com

Dell POWEREDGE R610 User Manual

Page 30

background image

30

About Your System

E1714

Unknown

error. Review

& clear SEL.

The system BIOS has

determined there has been

an error in the system, but

is unable to determine its

origin.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help."

E1715

Fatal I/O

error. Review

& clear SEL.

The system BIOS has

determined there has been

an error in the system.

Check the SEL for details

of the error message and

then clear the SEL.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help."

E1716

Chipset IERR

Bus ## Dev ##

Function ##.

Review &

clear SEL.

The system BIOS has

reported a chipset internal

error that resides in bus

##, device ##,

function##.

Check the SEL for details

of the error message and

then clear the SEL.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help."

E1717

CPU ##

internal

error. Review

& clear SEL.

The system BIOS has

determined that the

specified processor has had

an internal error.

Check the SEL for details

of the error message and

then clear the SEL.

Remove AC power to the

system for 10 seconds and

restart the system.
See "Troubleshooting the

Processors." If the

problem persists, see

"Getting Help."

Table 1-1. LCD Status Messages

(continued)

Code

Text

Cause

Corrective Actions