Dell POWEREDGE R610 User Manual
Page 25
About Your System
25
E1216
3.3V
Regulator
failure.
Reseat PCIe
cards.
3.3V voltage regulator has
failed.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
E1229
CPU # VCORE
Regulator
failure.
Reseat CPU.
Specified processor
VCORE voltage regulator
has failed.
Reseat the processor(s).
Processors."
If the problem persists,
E122A
CPU # VTT
Regulator
failure.
Reseat CPU.
Specified processor VTT
voltage regulator has failed.
Reseat the processor(s).
Processors."
If the problem persists,
E122C
CPU Power
Fault. Power
cycle AC.
A power fault was detected
when powering up the
processor(s).
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E122D
Memory
Regulator #
Failed.
Reseat DIMMs.
One of the memory
regulators has failed.
Reseat the memory
modules. See
E122E
On-board
regulator
failed. Call
support.
One of the on-board
voltage regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1310
Fan ## RPM
exceeding
range. Check
fan.
RPM of specified fan is
outside of the intended
operating range.
Problems."
Table 1-1. LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions