beautypg.com

Dell PowerEdge R900 User Manual

Page 35

background image

About Your System

35

Warning: The current memory
configuration is not
validated. Change it to the
recommended memory
configuration or press any
key to continue.

This warning message will be displayed

when there is no any memory

configuration error, but the memory

configuration is not recommended by

Dell.

Alert! Redundant memory
disabled! Memory
configuration does not
support redundant memory.

Redundant memory was set to enabled in

CMOS, but the current configuration

does not support redundant memory.

Attempting to update Remote
Configuration. Please wait…

Remote Configuration request has been

detected and is being processed.

Caution! NVRAM_CLR jumper is
installed on system board

NVRAM_CLR jumper is installed.

CMOS has been cleared. NVRAM_CLR

jumper should be removed.

CPUs with different cache
sizes detected

The system does not support running

with processors with mismatched cache

sizes

Decreasing available Memory

One or more DIMMs improperly seated

or faulty

Diskette drive 0 seek failure Faulty or improperly inserted diskette,

incorrect configuration settings in System

Setup program, loose diskette/tape drive

interface cable, or loose power cable

Replace the diskette.

Diskette read failure

Faulty diskette, faulty or improperly

connected diskette/tape drive interface

cable, or loose power cable

Diskette subsystem reset
failed

Faulty diskette/tape drive controller

Drive not ready

Diskette missing from or improperly

inserted in diskette drive

Table 1-6. System Messages

System Message