beautypg.com

Dell PowerEdge R900 User Manual

Page 17

background image

About Your System

17

Table 1-2. Hard Drive Indicators

Pattern

Green element

Amber eLement

Drive/slot state

Slot empty

Off

Off

The slot is empty, an

unsupported drive is

present, the drive has

been spun down for

removal (Ready for

Removal), or a new

drive has been inserted,

and the state has not

been updated by the

RAID controller.

Drive online

On

Off

The drive is either

online, ready, a hotspare

or a foreign drive.

Drive identify

(prep for removal)

On ~250mS
Off ~250mS

Off

The slot is being

identified because of a

user request (either a

drive identify or a

preparing for removal

was requested).

Drive rebuilding

On ~400mS
Off ~100mS

Off

The drive is being

written to, to make a

virtual disk redundant.

Drive failed

Off

On ~150mS
Off ~150mS

The RAID controller

can no longer access or

control (read/write to)

the drive because it has

detected an

unrecoverable fault

(after it has completed

its error handling) on

the drive.

Predicted Failure

(SMART)

On ~500mS
Off ~500mS
Off ~1000S

Off ~500mS
On ~500mS

Predictive failure event

has been reported by

the drive.