Dell PowerEdge R900 User Manual
Page 29
About Your System
29
E1811 HDD ## Rbld
Abrt
The specified hard drive
has experienced a rebuild
abort.
the problem persists, see
your RAID
documentation.
E1812 HDD ##
Removed
The specified hard drive
has been removed from the
system.
Information only.
E1913 CPU &
Firmware
Mismatch
The BMC firmware does
not support the processor.
Update to the latest BMC
firmware. See the
BMC
User’s Guide
for more
information on setup and
use of BMC.
E1A14 SAS Cable A
SAS cable A is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
E1A15 SAS Cable B
SAS cable B is missing or
bad.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
E2010 No Memory
No memory is installed in
the system.
Install memory. See
E2011 Mem Config
Error
Memory detected, but is
not configurable. Error
detected during memory
configuration.
E2012 Unusable
Memory
Memory is configured, but
not usable. Memory
subsystem failure.
E2013 Shadow BIOS
Fail
The system BIOS failed to
copy its flash image into
memory.
Table 1-5. LCD Status Messages
Code
Test
Causes
Corrective Actions