25

E1414 CPU #

Thermtrip

Specified microprocessor is

out of acceptable

temperature range and has

halted operation.

See "Troubleshooting

System Cooling" on

page 138. If the problem

persists, ensure that the

processor heat sinks are

properly installed. See

"Troubleshooting

Processors" on page 147.

NOTE:

The LCD continues

to display this message until

the system’s power cord is

disconnected and

reconnected to the AC

power source, or the SEL is

cleared using either Server

Assistant or the BMC

Management Utility. See the

Dell OpenManage

Baseboard Management

Controller User’s Guide for

information about these

utilities.

E1418 CPU #

Presence

Specified processor is

missing or bad, and the

system is in an

unsupported

configuration.

See "Troubleshooting

Processors" on page 147.

E141C CPU

Mismatch

Processors are in a

configuration unsupported

by Dell.

Ensure that your

processors match and

conform to the type

described in the

Microprocessor Technical

Specifications outlined in

your system’s

Getting

Started Guide

.

Table 1-5. LCD Status Messages

Code

Test

Causes

Corrective Actions