Dell PowerEdge RAID Controller H700 User Manual
Page 86

86
Configuring and Managing RAID
When you define the virtual disks, you can set the following virtual disk
parameters:
• RAID level
• Stripe element size
• Read policy
• Write policy
• Type of initialization
• Hot spare configuration
NOTE:
The default hard drive cache policy for a virtual disk composed with SAS
hard drives is
disabled and with SATA hard drives is enabled. The Virtual Disk
parameter can not be changed in the BIOS configuration Utility.
Table 6-2 shows the parameters that you can configure when defining
virtual disks.
Table 6-2. Virtual Disk Parameters and Descriptions
Parameter
Description
RAID Level RAID Level specifies whether the virtual disk is RAID 0, 1, 5, 6, 10,
50, or 60. The number of disks, disk capacity, the requirements for
fault tolerance, performance, and capacity should be considered when
selecting the RAID level. For more information, see "Summary of
Stripe
Element Size
Stripe Element Size specifies the size of the segments written to each
physical disk in a RAID 0, 1, 5, 6, 10, 50, and 60 virtual disk. You can
set the stripe element size to 8 KB, 16 KB, 32 KB, 64 KB, 128 KB,
256 KB, 512 KB, or 1024 KB. The default and recommended stripe
element size is 64 KB.
A larger stripe element size provides better read performance if your
system mostly does sequential reads.
PERC7.2_UG.book Page 86 Thursday, March 3, 2011 2:14 PM