Dell PowerEdge RAID Controller H700 User Manual
Page 133

Troubleshooting
133
All of the disks from
your previous
configuration are
gone. If this is an
unexpected message,
then please power off
your system and check
your cables to ensure
all disks are present.
Press any key to
continue, or 'C' to
load the configuration
utility.
The message indicates that
all configured disks were
removed. If the disks were
not removed, they are no
longer accessible. The SAS
cables for your system
might be improperly
connected.
Check the cable
connections and restart
the system.
If there are no cable
problems, press any key
or
The following virtual
disks are missing: (x)
If you proceed (or
load the configuration
utility), these
virtual disks will be
removed from your
configuration. If you
wish to use them at a
later time, they will
have to be imported.
If you believe these
virtual disks should
be present, please
power off your system
and check your cables
to ensure all disks
are present. Press any
key to continue, or
'C' to load the
configuration utility.
The message indicates that
some configured disks were
removed. If the disks were
not removed, they are no
longer accessible. The SAS
cables for your system
might be improperly
connected.
Check the cable
connections and restart
the system.
If there are no cable
problems, press any key
or
Table 9-1. BIOS Errors and Warnings
(continued)
Error Message
Probable Cause
Corrective Action
PERC7.2_UG.book Page 133 Thursday, March 3, 2011 2:14 PM