Physical disk failures and rebuild issues – Dell PowerEdge RAID Controller H700 User Manual
Page 144

144
Troubleshooting
Physical Disk Failures and Rebuild Issues
Table 9-4 describes issues related to physical disk failures and rebuilds.
Table 9-4. Physical Disk Failure and Rebuild Issues
Issue
Corrective Action
Rebuilding the physical
disks after multiple disks
become simultaneously
inaccessible.
Multiple physical disk errors in a single array typically
indicate a failure in cabling or connection and could
involve the loss of data.
You can recover the virtual disk after multiple physical
disks become simultaneously inaccessible. Perform the
following steps to recover the virtual disk:
CAUTION:
Follow the safety precautions to prevent
electrostatic discharge.
1
Turn off the system, check cable connections, and reseat
physical disks.
2
Ensure that all the disks are present in the enclosure.
3
Turn on the system and enter the
utility
and import the foreign configuration. Press
prompt to import the configuration, or press
enter the BIOS configuration utility and either import
or clear the foreign configuration.
If the virtual disk is redundant and transitioned to
Degraded state before going Offline, a rebuild operation
starts automatically after the configuration is imported.
If the virtual disk has gone directly to the Offline state
due to a cable pull or power loss situation, the virtual
disk is imported in its Optimal state without a
rebuild occurring.
You can use the BIOS Configuration Utility or
Dell OpenManage storage management application to
perform a manual rebuild of multiple physical disks.
For information on rebuilding a single physical disk,
see "Performing a Manual Rebuild of an Individual
PERC7.2_UG.book Page 144 Thursday, March 3, 2011 2:14 PM