beautypg.com

Terminal assignment, Display elements (status display) – Baumer G1-G2-G0-GE-GB-GXxxx User Manual

Page 52

background image

Manual_CANopen_BIDE_EN.docx

52/52

Baumer IVO GmbH & Co. KG

21.11.12

Villingen-Schwenningen, Germany

7.2.5. Terminal assignment

Pin

Terminal

Explanation

M12-connector (male/female)

1

GND

Ground connection relating to UB

2

UB

Supply voltage 10...30 VDC

3

GND

Ground connection relating to UB

4

CAN_H

CAN Bus signal (dominant High)

5

CAN_L

CAN Bus signal (dominant Low)


Terminals with the same designation are connected to each other internally and identical in their functions.
Maximum load on the internal clamps UB-UB and GND-GND is 1 A each.

Carefully plug the bus cover onto the D-SUB plug of the basic encoder, then press only via the sealing

rubber, taking care not to tilt it. The bus cover must rest fully against the basic encoder.

Tighten both the fastening screws firmly in the same direction.


The encoder housing and braided shield of the connecting cable are only ideally connected if the bus cover is
resting fully on the basic encoder (positive locking).


7.3. Display elements (status display)

A dual LED is integrated at the back of the bus cover.

LED green

LED red

Status

Off

Off

Supply voltage not connected

Flashing

Off

Pre-operational mode

On

Off

Operational mode

On

Off

Stopped/Prepared mode

Off

Flashing

Warning

Off

On

Error