7.2.5. Terminal assignment
Pin
Terminal
Explanation
M12-connector (male/female)
1
GND
Ground connection relating to UB
2
UB
Supply voltage 10...30 VDC
3
GND
Ground connection relating to UB
4
CAN_H
CAN Bus signal (dominant High)
5
CAN_L
CAN Bus signal (dominant Low)
Terminals with the same designation are connected to each other internally and identical in their functions.
Maximum load on the internal clamps UB-UB and GND-GND is 1 A each.
Carefully plug the bus cover onto the D-SUB plug of the basic encoder, then press only via the sealing
rubber, taking care not to tilt it. The bus cover must rest fully against the basic encoder.
Tighten both the fastening screws firmly in the same direction.
The encoder housing and braided shield of the connecting cable are only ideally connected if the bus cover is
resting fully on the basic encoder (positive locking).
7.3. Display elements (status display)
A dual LED is integrated at the back of the bus cover.
LED green
LED red
Status
Off
Off
Supply voltage not connected
Flashing
Off
Pre-operational mode
On
Off
Operational mode
On
Off
Stopped/Prepared mode
Off
Flashing
Warning
Off
On
Error