Detailed object list (ds-301) – Baumer G1-G2-G0-GE-GB-GXxxx User Manual
Page 25

Manual_CANopen_BIDE_EN.docx
25/52
Baumer IVO GmbH & Co. KG
21.11.12
Villingen-Schwenningen, Germany
4.4.2. Detailed object list (DS-301)
Object 1000
Device type
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
Multiturn:
00020196h
Singleturn:
00010196h
EEPROM
No
Description
Information on device profile and device type
Values
Multiturn:
Data 0, 1 = 96h 01h = 0196h = DSP-406 = Device profile for encoder
Data 2, 3 = 02h 00h = multiturn, absolute
Singleturn:
Data0 = Profile LOW
Data1 = Profile HIGH Data2 = Type
Data3
96
01
02
00
Data 0, 1 = 96h 01h = 0196h = DSP-406 = Device profile for encoder
Data 2, 3 = 01h 00h = singleturn, absolute
Data0 = Profile LOW Data1 = Profile HIGH
Data2 = Type
Data3
96
01
02
00
Object 1001
Error Register
Subindex
0
Data type
Unsigned 8
Access
Read only
Default
0h
EEPROM
No
Description
Current error code
Values
Bit0 = Generic error
Bit4 = Communication error (overrun, …)
Bit7 = Manufacturer specific
Object 1003
Predefined error field
CiA (CAN in Automation) defines around 200 different error codes here. In this document, only the
error codes of relevance for the sensor are described. This object saves the last occurred errors or
warnings.
Subindex
0
Data type
Unsigned 8
Access
Read write
Default
0
EEPROM
No
Description
Read: Number of errors or warnings
Write 0: Reset error
Values
0..8
Subindex
1..8
Data type
Unsigned 32
Access
Read only
Default
0
EEPROM
No
Description
Error or warning occurred, whereby subindex 1 is the ultimate, subindex
2 the penultimate entry etc.
Values
Not yet defined