Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual
Page 35
Manual_G0-GB-GXP5-GXU5_406_EN.docx
35/48
Baumer IVO GmbH & Co. KG
20.11.12
Villingen-Schwenningen, Germany
Object 6004
Position in increments
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
EEPROM
No
Description
Current position including offset
Values
0..Current overall measurement range -1 (Object 6002h)
Object 6200
Cyclic Timer for PD01
Subindex
0
Data type
Unsigned 16
Access
Read write
Default
302h
EEPROM
Yes
Description
Event timer for process data object (see object 1800-5)
Values
0 =
Cyclical transmission switched off
1..n..65535 = Repeat time cyclical transmission amounts to n ms.
Object 6500
Operating Status
Subindex
0
Data type
Unsigned 16
Access
Read only
Default
4h
EEPROM
No
Description
Operating data which is written with object 6000h
Values
Bit 0 sense of rotation = 0
Clockwise; 1 Counterclockwise
Bit 2 scaling function = 0
max. resolution; 1 saved resolution
Object 6501
Max. resolution in increments
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
2000h = 8192 = 13Bit
GXP5 / GXU5
40000h = 262144 = 18Bit
GBP5 / GBU5
EEPROM
No
Description
Maximum singleturn resolution in increments
Values
2000h = 8192 = 13Bit
GXP5 / GXU5
40000h = 262144 = 18Bit
GBP5 / GBU5