beautypg.com

Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual

Page 35

background image

Manual_G0-GB-GXP5-GXU5_406_EN.docx

35/48

Baumer IVO GmbH & Co. KG

20.11.12

Villingen-Schwenningen, Germany

Object 6004

Position in increments

Subindex

0

Data type

Unsigned 32

Access

Read only

Default

EEPROM

No

Description

Current position including offset

Values

0..Current overall measurement range -1 (Object 6002h)

Object 6200

Cyclic Timer for PD01

Subindex

0

Data type

Unsigned 16

Access

Read write

Default

302h

EEPROM

Yes

Description

Event timer for process data object (see object 1800-5)

Values

0 =

Cyclical transmission switched off

1..n..65535 = Repeat time cyclical transmission amounts to n ms.

Object 6500

Operating Status

Subindex

0

Data type

Unsigned 16

Access

Read only

Default

4h

EEPROM

No

Description

Operating data which is written with object 6000h

Values

Bit 0 sense of rotation = 0
 Clockwise; 1  Counterclockwise
Bit 2 scaling function = 0
 max. resolution; 1  saved resolution

Object 6501

Max. resolution in increments

Subindex

0

Data type

Unsigned 32

Access

Read only

Default

2000h = 8192 = 13Bit

 GXP5 / GXU5

40000h = 262144 = 18Bit

 GBP5 / GBU5

EEPROM

No

Description

Maximum singleturn resolution in increments

Values

2000h = 8192 = 13Bit

 GXP5 / GXU5

40000h = 262144 = 18Bit

 GBP5 / GBU5