Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual
Page 30
Manual_G0-GB-GXP5-GXU5_406_EN.docx
30/48
Baumer IVO GmbH & Co. KG
20.11.12
Villingen-Schwenningen, Germany
Object 1801
PDO2 parameters
See object 1800h, with the exception of subindex1, here COB ID is 280h + node ID
Object 1A00
PDO1 mapping
Subindex
0
Data type
Unsigned 8
Access
Read only
Default
0
EEPROM
No
Description
Biggest supported subindex
Values
1
Subindex
1
Data type
Unsigned 32
Access
Read only
Default
60040020h
EEPROM
No
Description
Describes the content of the PDO1 message
Values
6004h = Position
Object 1A01
PDO2 mapping
Subindex
0
Data type
Unsigned 8
Access
Read only
Default
0
EEPROM
No
Description
Biggest supported subindex
Values
1
Subindex
1
Data type
Unsigned 32
Access
Read only (defined by CiA as read write)
Default
60040020h
EEPROM
No
Description
Describes the content of the PDO2 message
Values
6004h = Position
Object 2100
Baud rate
Subindex
0
Data type
Unsigned 8
Access
Read write
Default
2 = 50 kBaud
EEPROM
Yes
Description
Read or reset the sensor baud rate.
After setting, parameters must be stored in the EEPROM with the
object 1010h and then the sensor re-initialized.
Values
0
10 kBaud
1
20 kBaud
2
50 kBaud
3
100 kBaud
4
125 kBaud
5
250 kBaud
6
500 kBaud
7
800 kBaud
8
1000 kBaud