beautypg.com

Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual

Page 30

background image

Manual_G0-GB-GXP5-GXU5_406_EN.docx

30/48

Baumer IVO GmbH & Co. KG

20.11.12

Villingen-Schwenningen, Germany

Object 1801

PDO2 parameters

See object 1800h, with the exception of subindex1, here COB ID is 280h + node ID

Object 1A00

PDO1 mapping

Subindex

0

Data type

Unsigned 8

Access

Read only

Default

0

EEPROM

No

Description

Biggest supported subindex

Values

1


Subindex

1

Data type

Unsigned 32

Access

Read only

Default

60040020h

EEPROM

No

Description

Describes the content of the PDO1 message

Values

6004h = Position

Object 1A01

PDO2 mapping

Subindex

0

Data type

Unsigned 8

Access

Read only

Default

0

EEPROM

No

Description

Biggest supported subindex

Values

1

Subindex

1

Data type

Unsigned 32

Access

Read only (defined by CiA as read write)

Default

60040020h

EEPROM

No

Description

Describes the content of the PDO2 message

Values

6004h = Position

Object 2100

Baud rate

Subindex

0

Data type

Unsigned 8

Access

Read write

Default

2 = 50 kBaud

EEPROM

Yes

Description

Read or reset the sensor baud rate.
 After setting, parameters must be stored in the EEPROM with the
object 1010h and then the sensor re-initialized.

Values

0

10 kBaud

1

20 kBaud

2

50 kBaud

3

100 kBaud

4

125 kBaud

5

250 kBaud

6

500 kBaud

7

800 kBaud

8

1000 kBaud