Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual
Page 29
Manual_G0-GB-GXP5-GXU5_406_EN.docx
29/48
Baumer IVO GmbH & Co. KG
20.11.12
Villingen-Schwenningen, Germany
Objekt 1029
Error Behavior (V1.04+)
Subindex
0
Data type
Unsigned 8
Access
ReadOnly
Default
1
EEPROM
No
Description
Biggest supported subindex
Values
1
Subindex
1
Data type
Unsigned 8
Access
ReadWrite
Default
1
EEPROM
Yes
Description
Behavior after communication error
Values
0h = change to Pre-Operational Mode
1h = no Mode-change
2h = change to Stop Mode
3h = reset node
Object 1800
PDO1 parameters
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
5
EEPROM
No
Description
Biggest supported subindex
Values
5
Subindex
1
Data type
Unsigned 32
Access
Read write
Default
180h + Node ID
EEPROM
Yes
Description
COB ID of the PDO
Values
180h + Node ID
Subindex
2
Data type
Unsigned 8
Access
Read write
Default
FEh
EEPROM
Yes
Description
PDO type
Values
1..n..F0h = PDO has synchronous characteristics (the PDO is
transmitted to each nth SYNC telegram)
FEh =
PDO has asynchronous characteristics (PDOs are
transmitted cyclically depending on the event timer and
event trigger)
Subindex
5
Data type
Unsigned 16
Access
Read write
Default
203h
EEPROM
Yes
Description
Event timer for process data object
Values
0 =
Cyclical transmission switched off
1..n..65535 =Repeat time cyclical transmission equals n ms.