Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual
Page 24

Manual_G0-GB-GXP5-GXU5_406_EN.docx
24/48
Baumer IVO GmbH & Co. KG
20.11.12
Villingen-Schwenningen, Germany
Object 1005
COB ID SYNC message
Subindex
0
Data type
Unsigned 32
Access
Read write
Default
80h
EEPROM
Yes
Description
Defined COB ID of the synchronization object (SYNC)
Values
Bit 31
not defined
Bit 30
1=Sensor generates SYNC messages, 0=generates no
SYNC message
Bit 29
1=29 bit SYNC COB ID (CAN 2.0B), 0=28 bit SYNC COB ID
(CAN 2.0A)
Bit 28..11 Bit 28..11 of the 29 bit SYNC COB ID
Bit 10..0 Bit 10..0 of the SYNC COB ID
Object 1008
Manufacturer Device Name
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
"GXP5", GBP5
"GXU5", GBU5
EEPROM
No
Description
Device name in ASCII
Values
Data 0..3:
"GBP5" = 47h 42h 50h 35h
GBP5 Multiturn
"GBU5" = 47h 42h 55h 35h
GBU5 Singleturn
"GXP5" = 47h 58h 50h 35h
GXP5 Multiturn
"GXU5" = 47h 58h 55h 35h
GXU5 Singleturn
Object 1009
Manufacturer hardware version
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
EEPROM
No
Description
Hardware version in ASCII
Values
Data 0..3 example:
31h 2Eh 30h 30h
= "1.00“
Object 100A
Manufacturer software version
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
EEPROM
No
Description
Software version in ASCII
Values
Data 0..3
see product label
exa.: 31h 2Eh 30h 30h
= "1.00“