Height adjustments, 24vdc, Dimming – Edge Lighting Cirrus Channel Suspension, Rectangular 1" Lens User Manual
Page 5

5
21: Connect the black remote power supply wire to the black
coaxial connector wire using a wire nut.
22: Connect the black remote power supply wire to the black
coaxial connector wire using a wire nut.
23: Place all connections into the junction box.
24: Secure the power canopy to the junction box using two #8-
32 screws.
22
21
T
POWER
CANOPY
CANOPY POST
#8-32
SCREWS
24
U
CANOPY
CANOPY
POST TAB
V
Height Adjustments
STANDOFF
POST TAB
COAXIAL CABLE
AIRCRAFT
CABLE
1
1
NOTE: Ensure remote DC power supply wires are present in
the junction box before continuing.
1: Adjust the fixture height by pushing the aircraft cable &
coaxial cable in to the standoff posts & canopy post.
2: If necessary push the tab on the standoffs & canopy post
to release the wire.
VOLTAGE
DROP
UP TO 33FT
3%
34FT-52FT
WIRE SIZE
14 AWG
53FT-86FT 87FT-130FT
12 AWG
10 AWG
8 AWG
WIRE LENGTH
IN FT
96W, 24VDC LOW VOLTAGE WIRE SIZE CHART
23.28 VDC
input 120VAC
WH (N)
BK (L)
input 0-10V
PUR
GRY
RED (24VDC+)
BLUE (RETURN-)
YELLOW (DIM RETURN-)
INPUT
120VAC
PHILIPS:
SUNRISE
SR1200ZTUNV
PSB-96W-010-24VDC
24VDC
RED 24VDC+
BLACK 24VDC-
PURPLE 1-10V
GRAY 1-10V
RED 120VAC (HOT)
BLACK (HOT)
WHITE (NEUTRAL)
GND
CHANNEL
DIMMING
GENERAL WIRING DIAGRAM
VOLTAGE AT END
OF THE WIRE
23.28 VDC
23.29 VDC
23.28 VDC
COAXIAL
CONNECTOR
COAXIAL
CABLE