Edge Lighting Everest User Manual
Page 2
2
C
CONICAL NIPPLE
STRAIN RELIEF TUBE
COAXIAL CABLE
3
3: Feed the coaxial cable through the conical nipple and flared
side of the strain relief tube. Slide the conical nipple and
strain relief tube down the coaxial cable.
D
COAXIAL CABLE
4
4: Feed the coaxial cable into the coaxial fixture connector. The
coaxial cable will come to a stop point.
8: Push the strain relief tube completely into the coaxial
fixture connector. Make sure the slot on the strain relief
tube is not inline with the M4 set screw.
9: Tighten the M4 set screw with the 2mm Allen wrench.
F
8
9
2MM ALLEN WRENCH
M4 SET SCREW
STRAIN RELIEF TUBE
COAXIAL FIXTURE
CONNECTOR
E
1.5MM ALLEN WRENCH
M3 SET SCREW
WRINKLE
OUTER METAL JACK
INNER WIRE
5
6
7
5: Keep feeding the coaxial cable in until the inner wire is
visible in the screw hole of the fixture connector tip. The
outer metal jacket will start to wrinkle.
6: Hold the fixture connector in place. Replace and tighten the
M3 set screw on fixture connector tip with the 1.5mm Allen
wrench.
7: Pull down the outer metal jacket to smooth the wrinkles.