Starter hose to right wing boom – Great Plains YP Fertilizer System User Manual
Page 24
![background image](/manuals/599154/24/background.png)
Great Plains Mfg., Inc.
24
Fertilizer System
407-197M
02/29/2008
Starter Hose to Right Wing Boom
134. Fold the planter to ensure that an adequate length of
hose is installed between the wings.
135. Select:
Refer to Figure 44 and Figure 45
136. Route the hose
:
• from the starter relief valve
• to the left wing hydraulic hose bundle or the high
rate hose (under the seed meter conduit, above
the row unit tool bar)
• along the hydraulic/high rate hose bundle to the
right wing
• to the elbow/tee at the center of the right boom.
137. Connect the hose to the adaptor
of the relief valve assembly. Secure with clamp
138. Allowing some slack, use cable ties every 16in or so
to secure the hose to the hydraulic/high rate bundle.
Refer to Figure 46 (which depicts older mount brackets)
139. At the right wing cut the hose to length at the elbow/
tee at the center of the boom and secure with clamp
.
Qty
Call
Part
Description
-
990-081R HOSE 3/4 ID 200PSI EPDM
2
800-257C CLAMP WRM DRV #20SS (.81-1.75)
Figure 44
Starter Relief Valve to Right Boom
27113
5
Figure 45
Wing-to-Wing Hose at Center
27101
Figure 46
Wing-to-Wing Hose at Right Wing