H.r. hose to left wing boom – Great Plains YP Fertilizer System User Manual
Page 18
Great Plains Mfg., Inc.
18
Fertilizer System
407-197M
02/29/2008
H.R. Hose to Left Wing Boom
96. Fold the planter to ensure that an adequate length of
hose is installed between the wings.
97. Select:
Refer to Figure 33 and Figure 34
98. Route the hose:
• from the H.R. relief valve
• to the left wing hydraulic hose bundle (under the
seed meter conduit, above the row unit tool bar)
• along the hydraulic bundle to the left wing
• to the elbow/tee at the center of the right boom.
99. Connect the hose to the adaptor
of the relief valve assembly. Secure with clamp
100. Allowing some slack, use cable ties every 16in or so
to secure the hose to the hydraulic bundle.
Refer to Figure 35 (which depicts a low rate boom on older
mount brackets)
101. At the left wing cut the hose to length at the elbow/
tee at the center of the boom and secure with clamp
.
Qty
Call
Part
Description
-
990-081R HOSE 3/4 ID 200PSI EPDM
2
800-123C CLAMP WRM DRV #16 SS (.68-1.5)
Figure 33
H.R. Relief Valve to Left Boom
27113
5
Figure 34
Wing-to-Wing Hose at Center
27101
Figure 35
Wing-to-Wing Hose at Left Wing
27102