Troubleshooting, General troubleshooting, Planting too much – Great Plains 3S-4010HDF Operator Manual User Manual
Page 59: Planting too little, Excessive seed cracking, Troubleshooting general troubleshooting

03/28/2012
196-522M
Great Plains Manufacturing, Inc.
Troubleshooting
55
Troubleshooting
General Troubleshooting
Problem
Cause
Solution
Planting too much
Excessive overlap
Adjust marker, page 18.
Incorrect Drive Type (Main Box)
Check sprocket set up (Seed Rate Manual).
Seed meter incorrectly set
Check handle against chart (Seed Rate Man-
ual).
Seed cup door too open (Main Box)
Narrow door opening for seed size (Seed
Rate Manual).
Seed size and/or density varies from
charts
Calibrate for your seed (Seed Rate Manual).
Incorrect tire size or pressure.
Check tires per page 89. Adjust air pressure.
For incorrect size, use calibration to compen-
sate until correct tires are installed.
Meter flutes damaged
Inspect and service as necessary.
Actual field size is different
Verify field size.
Planting too little
Excessive field speed
Slow down.
Pass gaps.
Adjust marker, page 18.
Incorrect Drive Type (Main Box)
Check sprocket set up (Seed Rate Manual).
Seed meter incorrectly set
Check handle against chart (Seed Rate Man-
ual).
Seed cup door too narrow (Main Box)
Widen door opening for seed size (Seed Rate
Manual).
Seed size and/or density varies from
charts
Calibrate for your seed (Seed Rate Manual).
Plugged opener seed tube
Lift drill, inspect and clear tube.
Contaminated seed or treatment build-
up in meters
Use new clean seed. Clean out meters.
Skipping chain or severely worn
sprockets
Adjust chain slack (page 63). Replace worn
sprockets.
Excessive seed cracking
Excessive field speed
Slow down.
Seed cup door too narrow (Main Box)
Open as needed for seed size (see Seed
Rate Manual).
Unclean seed.
Use clean seed.
Damaged, old or dry seed
Use clean, new seed.