beautypg.com

Opener frame height, Frame-mounted coulters, Frame height - frame mounted coulters – Great Plains 3S-4010HDF Operator Manual User Manual

Page 41: Opener frame height frame-mounted coulters, Frame-mounted coulters (fmc)

background image

Great Plains Manufacturing, Inc.

Adjustments

37

03/28/2012

196-522M

Opener Frame Height

Frame height adjustment methods depend on coulter
configuration:

Refer to Figure 40
1.

Frame-Mounted Coulters
frame height information begins on this page.

2.

Unit-Mounted Coulters
frame height information begins on page 41.

3.

No Coulters
use the same frame height setup as #2, page 41.

Frame-Mounted Coulters

Frame-mounted coulters are an optional alternative to
unit-mounted coulters. Only one type of coulter may be
installed. See page 85 for ordering information.

Frame-mounted coulters are used “in row” and not
“zone”. They are intended to prepare the soil directly
ahead of the seed furrow.

With frame-mounted coulters, the coulter depth controls
opener depth and performance. Set the frame height to
achieve the desired coulter depth.

There are three adjustments for frame-mounted coulters:

Refer to Figure 41
1.

Frame height - the running depth of all coulters as a
group. This is set by a hydraulic stop, the next topic.

2.

Individual coulter depth - a mechanical adjustment
for a few rows in tire tracks. See page 39.

3.

Individual coulter down-force - this is a spring adjust-
ment for rows in tracks, or all rows - in unusually light
or heavy no-till conditions. See page 40.

Frame Height - Frame Mounted Coulters

Refer to Figure 42
In regular or heavy no-till conditions, set

the coulter depth to about 1in (2.5cm) deeper than
seeding depth.

For example, if

the desired seeding depth is 1in (2.5cm), set
the coulters to run at 2in (5.1cm) deep.

Setting coulters too deep for conditions can cause
opener plugging and uneven or too-deep seed depth. In
light no-till or conventional till conditions, it may be nec-
essary to set coulter depth

to less than 1in (2.5cm)

below seeding depth

, or even

1

/

4

in (6mm) above seed-

ing depth.

In addition to checking depths at setup, be sure to check
actual seeding results while planting.

FigureSpacer:

Figure 40

Coulter Configurations

27211

1

2

3

FigureSpacer:

Figure 41

FMC Coulter Adjustment Points

20274
27215

4

5

6

FigureSpacer:

Figure 42

FMC Coulter to Opener Depth

27070

7

8

7

8

8

7

7

8

This manual is related to the following products: