beautypg.com

Interact at meter type definitions, Interact pro meter type definitions – ClearOne Interact Serial Command Guide User Manual

Page 61

background image

Page 56 of 56

If a channel has a numeric value of 0xff or an alpha value of ‘*’, the command is to be applied to all channels.
For example, a group value of 0x3 and a channel value of 0xff would mean that the command is to be applied
to all channels of group 3 (Mic inputs).

Interact AT Meter Type Definitions

Alpha

Numeric

Level

position for

Microphones

Level position for

Line Inputs and

Outputs

Level position for USB In, USB

Out, Telco Receive & Telco

Transmit

A

2

Level after
processing

Level after PEQ
and gain

Level after gain

R

5

Echo Return
Loss

N/A

N/A

E

6

Echo Return
Loss
Enhancement

N/A

N/A

T

7

ERL + ERLE

N/A

N/A

B

12

Pre PEQ,
Post Gain

N/A

N/A

Interact PRO Meter Type Definitions

Alpha

Numeric

Level of

Microphones

Level for Line

Inputs, Outputs,

USB In, USB

 Out, Headset

In, Headset Out

& Telco TX

Level for

Telco RX

Level for

Virtual

Reference

Level for

Processing

Channels

I

1

Input

Input

Input

Input to
compressor

A

2

After Gain

After Gain

After Gain

Output

Amount of
Compression

N

3

Output Level

G

4

After Gate

R

5

Echo Return
Loss (Room
Loss or ERL)

Echo Return
Loss (ERL)

E

6

Echo Return
Loss
Enhancement
(ERLE)

Echo Return
Loss
Enhancement
(ERLE)

T

7

Total Echo
Return Loss
(ERL +
 ERLE)

Total Echo
Return Loss
(ERL +
 ERLE)