Podupdate – pod/bob status update, Podver – pod version, Pp – phantom power – ClearOne Interact Serial Command Guide User Manual
Page 45
![background image](/manuals/598139/45/background.png)
Page 40 of 56
PODUPDATE – POD/BOB Status Update
This command reports the status of the POD / BOB’s for the unit. This command is read only!!!
ARGUMENT DETAILS
Name
Type
Size
Values
Type 1
Unsigned Integer
1
0 = Microphone POD / BOB not present
1 = Microphone POD present
2 = Microphone BOB present
3 = Interact EX present
(Null to query in text)
Type 2
Unsigned Integer
1
0 = Microphone POD / BOB not present
1 = Microphone POD present
2 = Microphone BOB present
Type 3
Unsigned Integer
1
0 = Microphone POD / BOB not present
1 = Microphone POD present
2 = Microphone BOB present
USB
Unsigned Integer
1
0 = USB / Headset BOB not present
1 = USB / Headset BOB present
TEXT FORM DETAILS
COMMAND FORM:DEVICE PODUPDATE [Type 1 Type 2 Type 3 USB]
PODVER – POD Version
This command reports the version of the FPGA code in the Break Out Box. This command is read only.
ARGUMENT DETAILS
Name
Type
Size
Values
Pod
Unsigned Integer
4
1 – 3 for Microphone BOBs
4 for USB/Headset
Value
String
12
(Sent with a Null in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE PODVER Pod [Value]
PP – Phantom Power
This command selects/reports the status of the phantom power for a microphone.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
3 (M)
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE PP