beautypg.com

Podupdate – pod/bob status update, Podver – pod version, Pp – phantom power – ClearOne Interact Serial Command Guide User Manual

Page 45

background image

Page 40 of 56

PODUPDATE – POD/BOB Status Update

This command reports the status of the POD / BOB’s for the unit. This command is read only!!!
ARGUMENT DETAILS

Name

Type

Size

Values

Type 1

Unsigned Integer

1

0 = Microphone POD / BOB not present
1 = Microphone POD present
2 = Microphone BOB present
3 = Interact EX present
(Null to query in text)

Type 2

Unsigned Integer

1

0 = Microphone POD / BOB not present
1 = Microphone POD present
2 = Microphone BOB present

Type 3

Unsigned Integer

1

0 = Microphone POD / BOB not present
1 = Microphone POD present
2 = Microphone BOB present

USB

Unsigned Integer

1

0 = USB / Headset BOB not present
1 = USB / Headset BOB present

TEXT FORM DETAILS
COMMAND FORM:DEVICE PODUPDATE [Type 1 Type 2 Type 3 USB]

PODVER – POD Version

This command reports the version of the FPGA code in the Break Out Box. This command is read only.
ARGUMENT DETAILS

Name

Type

Size

Values

Pod

Unsigned Integer

4

1 – 3 for Microphone BOBs
4 for USB/Headset

Value

String

12

(Sent with a Null in text)

TEXT FORM DETAILS
COMMAND FORM:DEVICE PODVER Pod [Value]

PP – Phantom Power

This command selects/reports the status of the phantom power for a microphone.
ARGUMENT DETAILS

Name

Type

Size

Values

Channel

Channel

1

See GroupAndChannels

Group

Group

1

3 (M)

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

TEXT FORM DETAILS
COMMAND FORM:DEVICE PP [Value]