Country – country selection, Cpreset – configuration preset, Decay – decay rate – ClearOne Interact Serial Command Guide User Manual
Page 23: Default – default the unit
![background image](/manuals/598139/23/background.png)
Page 18 of 56
COUNTRY – Country Selection
This command sets / reports the country for compliance.
ARGUMENT DETAILS
Name
Type
Size
Values
Value
Unsigned Integer
4
1 = US / Canada
2 = Europe
3 = Mexico
4 = Australia / New Zealand
5 = South Africa
6 = Japan
7 = Brazil
8 = South Korea
9 = China
10 = Singapore
11 = Taiwan
12 = Hong Kong
13 = India
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE COUNTRY [Value]
CPRESET – Configuration Preset
This command runs a configuration preset. There is no query for this command.
ARGUMENT DETAILS
Name
Type
Size
Values
Value
Unsigned Integer
4
1 – 4
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE CPRESET
DECAY – Decay Rate
This command selects/reports the decay rate for a microphone.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
3 (M)
Value
Unsigned Integer
2
1 = Slow
2 = Medium
3 = Fast
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE DECAY
DEFAULT – Default the Unit
Sets the unit to factory defaults. There is no query for this command.
ARGUMENT DETAILS
None
TEXT FORM DETAILS
COMMAND FORM: DEVICE DEFAULT