Gain – gain adjustment, Gate – gate status, Ghold – gate hold time – ClearOne Interact Serial Command Guide User Manual
Page 33
![background image](/manuals/598139/33/background.png)
Page 28 of 56
GAIN – Gain Adjustment
This command changes or reports back the gain for a specified channel.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
2, 3, 5, 7, 16, 17, 26, 27, 28, 29
(O, M, P, L, T, R, H, N, D, W)
Value
Signed Float
2
-99.90 – 99.90 dB **
(Null to query in text)
Absol / Rel
0
A = Absolute
R = Relative
Null = Relative
TEXT FORM DETAILS
COMMAND FORM:DEVICE GAIN
** Note: Values indicate entry range only. Actual internal range of the gain stage is from –14.00 to 18.00 dB
for Interact AT and from -65.00 to 20.00 dB for Interact PRO. Absolute values will be limited to the internal gain
range.
GATE – Gate Status
This command reports the gate status of Mics. This command is read only.
ARGUMENT DETAILS
Name
Type
Size
Values
Value
Hexadecimal
4
Bits 0 – 15 represent gate status on Mics 1 – 16
(Null sent in text, Value returned)
TEXT FORM DETAILS
COMMAND FORM:DEVICE GATE [Value]
GHOLD – Gate Hold Time
This command selects/reports the gate hold time for a microphone.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
3 (M)
Value
Unsigned Float
2
0.10 – 8.000 s
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE GHOLD