NLP – Non-Linear Processing
This command selects/reports the non-linear processing for a microphone.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
3 (M)
Value
Unsigned Integer
2
0 = Off
1 = Soft
2 = Medium
3 = Aggressive
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE NLP
NOM – Number of Open Microphones
This command selects/reports the setting of number of open microphone level adjust for an output.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
2 (O)
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE NOM
OFFA – Off Attenuation
This command selects/reports the off attenuation value for a microphone.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
3 (M)
Value
Unsigned Float
2
0.00 – 60.00 dB
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE OFFA