Filter – filter parameters, Flow – flow control – ClearOne Interact Serial Command Guide User Manual
Page 31
![background image](/manuals/598139/31/background.png)
Page 26 of 56
FILTER – Filter Parameters
This command selects/reports the parameters for a filter on a microphone.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
3, 5 (M, P)
Node
Unsigned Integer
1
1 – 3 for Group 3 (M)
1 – 4 for Group 5 (P)
Type
Unsigned Integer
1
Group 3 (M)
Group 5 (P)
0 = None
X
X
1 = All Pass
X
X
2 = Low Pass
X
X
3 = High Pass
X
4 = Low Shelf
X
5 = High Shelf
X
6 = PEQ
X
X
7 = CD Horn
X
11 = Notch
X
X
Frequency
Unsigned Float
4
Type
Values
0
0 (NULL in text)
2 – 11
20.00 to 20000.00 Hz
Gain
Signed Float
2
Type
Values
0 – 3, 11 0 (NULL in text)
6
-15.00 15.00 dB
Bandwidth
Unsigned Float
2
Type
Values
0 – 3
0 (NULL in text)
6, 11
0.05 – 5.00 Octaves
TEXT FORM DETAILS
COMMAND FORM:DEVICE FILTER
FLOW – Flow Control
This command selects/reports the flow control of the serial port on the unit. Hardware flow control is
implemented using DTR and DSR.
ARGUMENT DETAILS
Name
Type
Size
Values
Value
Unsigned Integer
4
0 = Off
1 = On
2 = Toggle
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE FLOW [Value]