HOOKD – Hook Flash Duration

This command selects/reports the hook flash duration.
ARGUMENT DETAILS

Name

Type

Size

Values

Channel

Channel

1

See GroupAndChannels

Group

Group

1

17 (R)

Value

Unsigned Integer

2

50 – 1000 ms
(Null to query in text)

TEXT FORM DETAILS
COMMAND FORM:DEVICE HOOKD [Value]

LABEL – Label

This selects/reports the label of the specific channel or the unit.
ARGUMENT DETAILS

Name

Type

Size

Values

Channel

Channel

1

See GroupAndChannels

Group

Group

1

2, 3, 5, 7, 9, 16, 17, 26, 27, 28, 29
(O, M, P, L, U, T, R, H, N, D, W)

Reserved

Unsigned Integer

2

0

Label

String

32

For group U, 1 – 11 characters
All other, 1 – 32 characters
(Null to query in text)

TEXT FORM DETAILS
COMMAND FORM:DEVICE LABEL [Value]

LOCALNUM – Local Number

This command sets or reports back the current value of the local number.
ARGUMENT DETAILS

Name

Type

Size

Values

Channel

Channel

1

See GroupAndChannels

Group

Group

1

17 (R)

Reserved

2

0

Number

String

16

1 – 16 Chars of ‘0’ – ‘9’, ‘A’ – ‘D’, ‘*’, ‘#’, ‘,’
(Null to query in text)

TEXT FORM DETAILS
COMMAND FORM:DEVICE LOCALNUM [Number]