Ramp – ramp gain adjustment, Redial – dial the last number again, Refset – reference set – ClearOne Interact Serial Command Guide User Manual
Page 48: Reset – reset
![background image](/manuals/598139/48/background.png)
Page 43 of 56
RAMP – Ramp Gain Adjustment
This command starts / stops the gain ramp on a specified channel. There is no query for this command!
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
2, 5, 7 (O, P, L)
Rate
Signed
Integer
1
-50 to +50 dB / s
If Rate = 0, the ramp will stop
If Rate < 0, the gain will ramp down
If Rate > 0, the gain will ramp up
Target
Signed
Integer
1
-65.00 to +20.00 dB
If NULL in text (0x80) in binary, the ramp will use the gain range as
the target.
TEXT FORM DETAILS
COMMAND FORM:DEVICE RAMP
REDIAL – Dial the last number again
This command redials the last number. There is no query for this command.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
17 (R)
Reserved
2
0
TEXT FORM DETAILS
COMMAND FORM:DEVICE REDIAL
REFSET – Reference Set
This command selects/reports the output a virtual reference uses for gain tracking.
ARGUMENT DETAILS
Name
Type
Size
Values
Channel
Channel
1
See GroupAndChannels
Group
Group
1
20
(B)
Output Channel
Channel
2
See 2 (O) in GroupAndChannels
TEXT FORM DETAILS
COMMAND FORM:DEVICE REFSET
RESET – Reset
Resets the unit. There is no query for this command.
TEXT FORM DETAILS
COMMAND FORM: DEVICE RESET