Electroguard, Prefix 80 series exit device, 2general description – SARGENT FM8700 Surface Vertical Rod Exit Device User Manual
Page 5: Parts breakdown 3, Electrical specifications
![background image](/manuals/598024/5/background.png)
2
General Description
The SARGENT 59- Electroguard™ exit device is designed for areas which require a delayed egress with a door
alarm when any attempt is made to violate the door. The Electroguard™ can be tied into a fire alarm system,
indicate latchbolt status and control an alarm at a remote location when the door is in violation.
NOTE: Proper connections and appropriate peripheral hardware are required.
All components must be installed according to prevailing electrical codes.
BC-Prefix Option
The BC prefix for Electroguard™ indicates that the unit has been programmed to comply with the section of the
BOCA code relating to delayed egress.
BOCA allows for automatic reset of the delayed egress unit. Under BOCA, the unit can automatically reset thirty (30)
seconds after the door has been cycled. If the door is opened any time during the thirty (30) seconds, the timer in the
unit resets and waits another thirty (30) seconds before rearming. This requires a door position switch.
Note: If a door position switch is not used (Blue wire connected to Black wire), the unit will automatically reset in
30 seconds.
There are no user serviceable parts on the Electroguard™ PCB module assembly.
• Input Voltage: 24VDC regulated/filtered
• Power Consumption: 180 mA Unloaded (typical/standard), 375 mA Loaded (with Optional features)
• Output Relays: Form C, 1 Amp 24VDC
• Operating Temp: 0°C to 49°C (32°F to 120°F)
Electrical Specifications
Part No.
Description
52-1292
Harness Assembly - “E” and “F” size rails
52-1293
Harness Assembly - “J” and “G” size rails
52-4837
PCB Module Replacement Pack - Standard
52-4838
PCB Module Replacement Pack - BOCA (BC prefix)
Consult factory
Rail Assembly
Consult factory
Chassis Assembly
Consult factory
Insert Assembly
Consult factory
Chassis Cover
52-2204
Latchbolt Harness and Switch Assembly for 59-8800 and 8500 Rim Devices
52-2217
Surface Vertical Rod Harness and Switch Assembly for 59-8700 Devices
52-2220
Concealed Vertical Rod Harness and Switch Assembly for 59-8600 and 8400 Devices
52-2224
Latchbolt Harness and Switch Assembly for 59-8900 and 8300 Mortise Devices
Parts Breakdown
3
Chassis
Cover
Insert
Assembly
Chassis
assembly
Harness
Assembly
PCB Module
Assembly
Rail Assembly
5 1-800-810-WIRE • www.sargentlock.com • A7690E
Copyright © 2013, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
04/15/13
Electroguard
®
59- Prefix 80 Series Exit Device
- PR8700 Center & Top Latch Surface Vertical Rods for Pair of Doors PP8700 Center & Top Latch Surface Vertical Rods for Pair of Doors HC8700 Hurricane Code Surface Vertical Rod Exit Device NB8700 Top Latch Surface Vertical Rod 8700 Surface Vertical Rod Exit Device SP8600 Center & Top Latch Concealed Vertical Rods PR8600 Center & Top Latch Concealed Vertical Rods PP8600 Center & Top Latch Concealed Vertical Rods LR8600 Low Profile Center & Top Latch Concealed Vertical Rod Exit Devices LP8600 Low Profile Center & Top Latch Concealed Vertical Rod Exit Devices NB-WD8600 Concealed Vertical Rod Exit Device for Wood Doors WD8600 Concealed Vertical Rod Exit Device for Wood Doors NB-MD8600 Concealed Vertical Rod Exit Device for Metal Doors MD8600 Concealed Vertical Rod Exit Device for Metal Doors NB-MD8400 Series Narrow Style Concealed Vertical Rod MD8400 Series Narrow Style Concealed Vertical Rod LS8600 Low Profile Center & Top Latch Concealed Vertical Rods WS8900 Mortise Lock 8900 Mortise Lock Exit Device 8300 8888 Reversible Rim Exit Device 8800 Rim Exit Device 8500 Narrow Design Rim Exit Device HC8800 Rim Exit Device