beautypg.com

Electroguard, Prefix 80 series exit device, 4installation instructions (continued) – SARGENT FM8700 Surface Vertical Rod Exit Device User Manual

Page 18

background image

connector

Chassis

Rail wire &

connector

Chassis

arm

Left Hand Reverse Bevel

Illustrated

Rail assembly

Cover

Push rail

Wire & connector

Inside diameter

Inside Of

Door

H. Installing 59-8900/12-59-8900 Series Mortise Lock

Exit Device

CAUTION – BEFORE STARTING:
• Check hand of door (This device is handed and not reversible)
• Door should be fitted and hung
• Verify box label for size of exit device, function and hand

Wire &

Mortise lock

body

Vertical

reverse line (of

chassis)

IMPORTANT: Surface of door where exit

device is to be applied must be flush.

Clear away any raised projections to

allow exit device to rest on flat surface

of door.

PREPARE DOOR AND MOUNT LOCK
Refer to Instruction sheet A6705

1. Feed wire and connector through the mortise opening and out the inside diameter

CL

4

Installation Instructions (Continued)

18 1-800-810-WIRE • www.sargentlock.com • A7690E