Electroguard, Prefix 80 series exit device, System wiring examples (continued) 9 – SARGENT FM8700 Surface Vertical Rod Exit Device User Manual

Page 27

background image

Red

(+24),

2

White, 3

Black, (-Return), 1

Green (EG), 4

6, Blue (DS)

3520 24VDC 1.0AMP Regulated and Filtered Power Supply

Line voltage

fuse (1 AMP)

Connector to

power on LED

HOT

110-120 VAC

NEUT

GND

123

AC

F

Low voltage AC

From transformer

AC

DC DC

Output

NOTE: This drawing shows the
BPS Series. The PM Series
has no line voltage input, fuse
or connector to power on LED

2.5 AMP polyswitch breaker

Red
Black

Unconnected
terminal for

switch hookup

Plug pigtail harness
connector into

8-pin hinge connector

at frame side of door

Electric hinge with

8-pin connectors

Battery pack

Raceway harness with 8 & 4-pin
connectors. The 4-pin

connectors are not used here.

Brown (RAR - C), 7

RAR contact shown in

rail powered on state

3287

Door status

switch

59- 80 Series Rail with
8 & 4-pin connector. The
4-pin connector is not

used here.

Note: Typical raceway location is
shown. Other locations may exist

depending on door type.

4380H

(remote)

horn

8, Yellow (RAR - NO)

8 6 4

5

2

3 1

(+)

Pigtail harness
assembly with

8-pin connector

When door is closed,
the green wire is

shorted to white wire

Green (NC)

White (C)

(

-

)

4291

Keypad

(inside)

C

1 2 3
4 5 6
7 8
*

9

0 #

NO

(-)

(+)

Wiring Notes:
1. Rail, raceway, electric hinge and

pigtail 8-pin connector terminations
and wire colors all match.

2. Tape or cap off ends of unused pigtail

wires (not shown) to ensure that they
don’t short to anything.

3. A fire alarm tie-in is required on fire

rated openings.

4. The fire alarm contact (when required)

must be wired to drop 24VDC power
to rail. In this case, terminate fire alarm
contact between the red (+ 24VDC)
wire and supply + 24VDC output.

5. Connect the white wire to the black

(-return) wire.

Sample Wiring #2 – 59- Electroguard™ Exit Device with inside Keypad,
Fire Alarm, Door Status and Remote Horn

A valid code entry at the 4291 (Inside) keypad shunts the Electroguard™ exit device and allows egress for a time period
programmable at the keypad. During a fire alarm condition, the contact opens which de-energizes the rail electromagnet and
allows immediate egress. When the rail is armed and the door is forced open, the 3287 door status switch signals the rail
sounding the rail alarm. When the rail is armed and violated, the remote alarm relay sends 24VDC to the 4380H remote horn.

Normally Closed Fire

Alarm Contact

(If Required)

7

5, Orange (EI)

Voltage adjust for

battery backup

System Wiring Examples (Continued)

9

27 1-800-810-WIRE • www.sargentlock.com • A7690E

Copyright © 2013, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

04/15/13

Electroguard

®

59- Prefix 80 Series Exit Device