Profile Series v.G1.5/LK Mortise Lock

Option #3 – Hard Power/Remote Unlock (91-) Combined With Forced/Propped Door (DM-)

Fig. 1

A

B

C

D

Installation

1. ElectroLynx® System Wiring Instructions (Fig. 1, 1A and Fig. 3):

a. Look for the mating part on ASSA ABLOY doors and frames.
b. Plug in all connectors during product installation (Fig. 3).
c. Hard wire hard power and/or remote unlock (REX) (Fig. 3).

2. Non-ElectroLynx® System Wiring Instructions (Fig. 1 and Fig. 3):

a. Cut the 8 and 4-pin connectors off the Remote Power/Unlock

harness and hard wire to non-ElectroLynx® door harness.

b. Remote power requires three conductors; and remote unlock

and DM- require two conductors.

c. Hard wire door harness to power transfer device.
d. Hard wire door status switch to power transfer device.

*IMPORTANT: (6) “AA” batteries MUST be removed from

controller when using 3267 power supply.

Ground Tab E3

(TB2) Remote/Power

Unlock Connector

(TB1) Motor

Connector

Door

* Inside

Escutcheon

Outside

Escutcheon

A

Note: Refer to 3267 Power

Supply

Instruction Sheet A7477

Fig. 3A

Remote Powering and Remote Unlocking

ElectroLynx Wiring System

QC4A Electric Hinge

With 8-pin connectors,

8 wires and pigtail harness

ElectroLynx Door Harness

With 8 and 4-pin connectors - Harness location is

dependent

on door type

C

B

Normally Open

Momentary Switch

(Remote Unlock

REX Option)

1 - Red

2 - Black

3 - White

4 - Orange

5 - Blue

6 - Brown

7 - Y

ellow

8 - Green

1 2 3 4 5 6 7 8

+9V

(-)

REX

REX

Data Out

Data In

RT

S

EGND

120VAC L/N/G

* 3267 9VDC

Power Supply

1 - Black
2 - Red
3 - White (NO)
4 - Green
5 - Orange (C)
6 - Blue
7 - Brown
8 - Yellow

-9VDC

+9VDC

EGND

Door Status Switch

*Wire for switch contact closure

when door is opened - Typical

locations shown in Fig. 1

D

1 - Red
2 - Black
3 - White (C)
4 - Green (*NC)

321

4 - Tan
3 - Pink

1 - Black
2 - Red
3 - White (NO)
4 - Green
5 - Orange (C)
6 - Blue
7 - Brown
8 - Yellow

1 - Red
2 - Black
3 - White
4 - Green