Profile Series v.G1.5/LK Mortise Lock
Option #3 – Hard Power/Remote Unlock (91-) Combined With Forced/Propped Door (DM-)
Fig. 1
A
B
C
D
Installation
1. ElectroLynx® System Wiring Instructions (Fig. 1, 1A and Fig. 3):
a. Look for the mating part on ASSA ABLOY doors and frames.
b. Plug in all connectors during product installation (Fig. 3).
c. Hard wire hard power and/or remote unlock (REX) (Fig. 3).
2. Non-ElectroLynx® System Wiring Instructions (Fig. 1 and Fig. 3):
a. Cut the 8 and 4-pin connectors off the Remote Power/Unlock
harness and hard wire to non-ElectroLynx® door harness.
b. Remote power requires three conductors; and remote unlock
and DM- require two conductors.
c. Hard wire door harness to power transfer device.
d. Hard wire door status switch to power transfer device.
*IMPORTANT: (6) “AA” batteries MUST be removed from
controller when using 3267 power supply.
Ground Tab E3
(TB2) Remote/Power
Unlock Connector
(TB1) Motor
Connector
Door
* Inside
Escutcheon
Outside
Escutcheon
A
Note: Refer to 3267 Power
Supply
Instruction Sheet A7477
Fig. 3A
Remote Powering and Remote Unlocking
ElectroLynx Wiring System
QC4A Electric Hinge
With 8-pin connectors,
8 wires and pigtail harness
ElectroLynx Door Harness
With 8 and 4-pin connectors - Harness location is
dependent
on door type
C
B
Normally Open
Momentary Switch
(Remote Unlock
REX Option)
1 - Red
2 - Black
3 - White
4 - Orange
5 - Blue
6 - Brown
7 - Y
ellow
8 - Green
1 2 3 4 5 6 7 8
+9V
(-)
REX
REX
Data Out
Data In
RT
S
EGND
120VAC L/N/G
* 3267 9VDC
Power Supply
1 - Black
2 - Red
3 - White (NO)
4 - Green
5 - Orange (C)
6 - Blue
7 - Brown
8 - Yellow
-9VDC
+9VDC
EGND
Door Status Switch
*Wire for switch contact closure
when door is opened - Typical
locations shown in Fig. 1
D
1 - Red
2 - Black
3 - White (C)
4 - Green (*NC)
321
4 - Tan
3 - Pink
1 - Black
2 - Red
3 - White (NO)
4 - Green
5 - Orange (C)
6 - Blue
7 - Brown
8 - Yellow
1 - Red
2 - Black
3 - White
4 - Green