beautypg.com

Profile series v.g1.5/lk mortise lock, Electrolynx lock wire connections, Door position switch (dps) – SARGENT Profile Series v.G1.5 Mortise Locks User Manual

Page 16

background image

16 1-800-810-WIRE • www.sargentlock.com • A7855C

Copyright © 2014, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved.

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

01/31/14

Profile Series v.G1.5/LK Mortise Lock

Before the controller is attached to the door (Fig. 1A):

1. Attach the reader cable to the controller.
2. Attach the connector from the lock into the bottom

of the circuit board (TB2, Fig. 3B).

3. Plug the ground wire into the bottom of the controller assembly (E1, Fig. 3B).
4. Route the connector from the raceway through the top opening between the controller and the escutch-

eon, along the battery keeper, back under the bottom opening between the controller and escutcheon and

attach at the bottom of the controller.
Note: Connectors go on only one way.
Do not offset connectors and make sure they are completely seated.

A

A

B

C

D

Fig. 1

ElectroLynx Lock Wire Connections

Door Position Switch (DPS)

Install the SARGENT 3287 Door Status Switch according to

instructions included in the kit.
Wire the 3287 Door Status Switch to the ElectroLynx frame har-

ness and to the door status wires:

1. Connect the common wire of the switch to the common wire

of the harness.

2. Connect the normally open wire of the switch to the door

position wire of the harness.
Note: The third wire (normally closed) of the 3287 Door Sta-

tus Switch is not used for this type of system.

Inside

Escutcheon

(Back)

Inside of Door

1

1

2

3

4

4

4

2

Inside

Escutcheon

(Front)

Fig. 1A