Profile Series v.G1.5/LK Mortise Lock
Step #7 – Inside Escutcheon Wire Connections
Images are shown without gasket.
If gasket is necessary, refer to Step #5.
Before the controller is attached
to the door:
1. Attach the reader assembly
ribbon cable into the back
of the controller assembly
(side that faces towards
the door when mounted
(Fig. 7A).
2. Attach the ground wire to
the bottom of the controller
assembly (E1, Fig. 7A).
3. Connect the cable from
the cylindrical lock to
the bottom of the controller
assembly (TB1, Fig. 7B).
If
Hardwiring is required,
go to “Hardwire Wiring Options”
on page 14.
4. Place extra wire inside door hole
and/or outside escutcheon,
being careful not to pinch wires.
Connectors go on only one way.
Do not offset connectors, and make
sure they are completely seated.
Ground
Wire
Fig. 7A
1
Outside
Escutcheon
2
Ground
Wire
Reader
Cable
Reader
Ribbon
Cable
1
Inside
Escutcheon
(Back)
3
TB1
Inside of Door
3
2
Lock
Cable
Red
Black
Red
Black
Green
Green
With
Deadbolt
Without
Deadbolt
Fig. 7B
Lock Body
Wire Harness
Lock Body
Wire Harness
TB1
Ground
Motor
Connector
Remote Power
REX Connector
TB1
TB1
3