To Enter the Emergency Code
99# Master Code*
Yellow LED blinks
50# 02#
Yellow LED blinks
Emergency (1-6 digits)*
Yellow LED blinks quickly
Emergency (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Emergency Code defaults to a 10 second unlock time and will override a thrown deadbolt on a mortise lock.
• Factory Emergency Code is 4321
To Enter or Change the Supervisor Code
99# Master Code*
Yellow LED blinks
50# 1# 03#
Yellow LED blinks
Supervisory (1-6 digits)*
Yellow LED blinks quickly
Supervisory (1-6 digits)*
Yellow LED blinks Slowly (If solid, see note)
*
Yellow LED goes out
Enter A User Code
99# Master Code* or Supervisory Code*
Yellow LED blinks
50# 1# (User Number 04-100)#
Yellow LED blinks
User Code (1-6 digits)*
Yellow LED blinks quickly
User Code (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Enter A Passage (Maintained) Code
99# Master Code*
Yellow LED blinks
50# 0# (User Number 04-100)#
Yellow LED blinks
User Code (1-6 digits)*
Yellow LED blinks quickly
User Code (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Enter A One Time User Code
99# Master Code* or Supervisory Code*
Yellow LED blinks
50# 5# (User Number 04-100)#
Yellow LED blinks
User Code (1-6 digits)*
Yellow LED blinks quickly
User Code (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
To Deactivate/Reactivate “Beep” With Key Stroke
99# Supervisory or Master Code*
Yellow LED blinks
30# 0# 0# (Off) (1# = On)
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Note: If turning beep off, not audible on last two steps.
To Clear the Entire Memory
99# Master Code*
Yellow LED blinks
46# 00000# 00000#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED goes solid and begins to blink
*
Yellow LED goes out (If solid, see note)
This deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back to 1234*,
Door Number to 0001 and Unlock Time to 5 seconds. If the Master Code is not known, factory assistance will be
required to clear the memory. Call 1-800-810-9473.