Chain programming – SARGENT Profile Series v.G1.5 Exit Devices User Manual
Page 11
9
For installation assistance, contact SARGENT at 800-810-WIRE (9473)
Keypad Programming Instructions for the Profile Series v. G1 Lock
Using Master Code 4732 and above information, the lock would be programmed as follows:
99# 4732* 50# 1# 05# 875* 875* 3# 12# 2226* 2226* 2# 08# 5444* 5444* 1# 50# 3367* 3367*
If all user codes are type 1, it is not necessary to enter the type number with each entry.
The format now simplifies to:
99# Master or Supervisor Code* User Number a# User code a* User Code a* UNb# UCb* UCb* UNc# UCc*
UCc*....... UN_# UC_* UC_**
An example with three user codes is shown below:
Using Master Code 45988 and above information, the lock would be programmed as follows:
99# 45988* 07# 77* 77* 15# 67832* 67832* 91# 7568* 7568**
To chain the User Number delete procedure:
99# Master Code* User Number a#** UNb#** UNc#**....... UN_#****
Using the information from the above example:
99# 45988* 07#** 15#** 91#****
Type
User Number
User Code
1
07
77
1
15
67832
1
91
7568
When programming multiple User Numbers and Codes into the LK, G1-LU, G1-PK, G1-TU and G1 TP Lock, it is
not necessary to leave and re-enter the programming Mode (50) for each entry. Multiple entries may be chained
together and the three different types of user codes (Standard, Passage and One Time) may be mixed.
The format to be used is as follows:
“T” is the Type of user code with “1” Standard, “2” Passage and “3” One Time.
“UN_” is User Number (04-99)
“UC_” is User Code (2 to 6 digits) which correlates with the User Number
99# Master or Supervisor Code* 50# Type# User Number a# User Code a*
User Code a* T# UNb# UCb* UCb* T# UNc# UCc* UCc* ...... T# UN_# UC_* UC_**
An example with four user codes is shown below:
Type
User Number
User Code
1
05
875
3
12
2226
2
08
5444
1
50
3367
-
+
-
+
-
+
-
+
+
-
+
-
LK
LU
PK
Chain Programming
5
Label indicates version
of electronics
© SARGENT Manufacturing Company