Tweco 550i Transmig User Manual
Page 75
TRANSMIG 350i, 450i, 550i
Manual 0-5205
5-3 POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS
Note that due to the dangers of stray output currents damaging fixed wiring, the integrity of fixed wiring
supplying Cigweld welding power sources should be inspected by a licensed electrical worker in accordance
with the requirements below -
1. For outlets/wiring and associated accessories supplying transportable equipment - at least once
every 3 months; and
2. For outlets/wiring and associated accessories supplying fixed equipment - at least once every 12
months.
D. Voltage Reduction Device (VRD)
Units fitted with VRD's, shall have the periodic tests outlined in Table 6-2 below conducted by an accredited
CIGWELD service provider. Testing shall be conducted at intervals as outlined below -
1. For transportable equipment, at least once every 3 months; and
2. For fixed equipment, at least once every 12 months.
Description
Required Parameters
VRD Open Circuit Voltage Less than 35V; at nominal input voltage
VRD Turn OFF Resistance
Less than 200 ohms
VRD Turn ON Time
Less than 0.3 seconds
Table 5-3: VRD Periodic Tests
E. General Maintenance Checks
Welding equipment should be regularly checked by an accredited Cigweld Service Provider to ensure that:
1. Flexible cord is of the multi-core tough rubber or plastic sheathed type of adequate rating, correctly
connected and in good condition.
2. Welding terminals are in suitable condition and are shrouded to prevent inadvertent contact or short
circuit.
3. The Welding System is clean internally, especially from metal filing, slag, and loose material.
F. Accessories
Accessory equipment, including output leads, electrode holders, torches, wire feeders and the like shall be
inspected at least monthly by a competent person to ensure that the equipment is in a safe and serviceable
condition. All unsafe accessories shall not be used.
G. Repairs
If any parts are damaged for any reason, it is recommended that replacement be performed by an ac-
credited Cigweld Service Provider.
Power Source Calibration
A. Schedule
Output testing of all Cigweld Inverter Power Sources and applicable accessories shall be conducted at
regular intervals to ensure they fall within specified levels. Calibration intervals shall be as outlined below -
1. For transportable equipment, at least once every 3 months; and
2. For fixed equipment, at least once every 12 months.
If equipment is to be used in a hazardous location or environments with a high risk of electrocution as
outlined in AS 1674.2 - 2007, then the above tests should be carried out prior to entering this location.