beautypg.com

Tweco 550i Transmig User Manual

Page 23

background image

TRANSMIG 350i, 450i, 550i

Manual 0-5205 3-3

INSTALLATION, OPERATION AND SETUP

taken to prevent the earthing of the workpiece increasing the risk of injury to users, or damage to other

electrical equipment. Where necessary, the connection of the workpiece to earth should be made by

direct connection to the workpiece, but in some countries where direct connection is not permitted,

the bonding should be achieved by suitable capacitance, selected according to national regulations.

6. Screening and Shielding
Selective screening and shielding of other cables and equipment in the surrounding area may allevi-

ate problems of interference. Screening the entire welding installation may be considered for special

applications.

3.06 Transmig 350i, 450i, 550i Power Source Controls, Indicators and Features

6

8

1

2

3

4

5

7

9

A-10627

13

14

12

10

11

A-10628

This manual is related to the following products: