Tweco 550i Transmig User Manual
Page 30

TRANSMIG 350i, 450i, 550i
INSTALLATION, OPERATION AND SETUP 3-10 Manual 0-5205
15. Advanced Features
The TRANSMIG 350i, 450i and 550i have a series of Advanced features that allow the control of multiple
parameters.
These are accessed by pressing the AMPS and VOLTS knobs at the same time.
Once in the Advanced Features mode, turn the AMP control to select the Parameter, and turn the VOLTS
control to adjust the value.
A-10633
Figure 3-2: Advanced Features
Program Number
Description
Amps
A-10634
Volts
A-10635
P01
SPOT TIME, adjustable from 0.5 to 5.0 seconds
P02
BURN BACK TIME, adjustable from 0.01 to 2.00 seconds
P03
PRE FLOW TIME, adjustable from 0.01 to 9.99 seconds
P04
POST FLOW TIME, adjustable from 0.01 to 9.99 seconds
P05
MMAW (Stick) HOT START CURRENT, adjustable from 10 to 100A
P06
CREEP FEED SPEED, adjustable from 0.05 to 20 MPM
P07
Wirefeed speed units, change between IPM and MPM
P08
Displays Software revision
Table 3-1: Advanced Features