Description

Possible

Cause Remedy

Remarks

5 E11 error code displayed

Over Primary supply
(input) voltage at primary
capacitors is exceeded for
one second.

Primary

supply

voltage is greater
than the nominal
voltage plus 10%.

Have an accredited

Thermal Arc Service
Agent or a qualified
electrician check the
Primary voltage.

Weld current
ceases.
Buzzer sounds
constantly.
Error code E11
automatically will
reset when the
voltage reduces.

6 E14 error code displayed

Under mains supply (input)
voltage warning primary
capacitors is reduced for
one second.

Mains supply voltage

is less than the
nominal operating
voltage less 10%.

Have an accredited

Thermal Arc Service
Agent or a qualified
electrician check the
Mains voltage.

Weld current
available.
Buzzer sounds
intermittently.
Error code E14
automatically will
reset when the
voltage increases.

7 E12 error code displayed

Under mains supply (input)
voltage primary capacitors
is reduced for one second.

Mains supply voltage

is down to a
dangerously low
level.

A

B

Have an accredited
Thermal Arc Service
Agent or a qualified
electrician check the
Mains voltage.

Have an accredited
Thermal Arc Service
Agent or a qualified
electrician check the
primary cable and
fuses.

Weld current
ceases. Buzzer
sounds constantly.
Error code E12
automatically will
reset when the
voltage increases.

8 E81 error code displayed

Wrong Primary supply
(input) voltage connected.

When 3 phase

machine is first
turned ON with the
wrong Primary
supply (input)
voltage connected.

Have an accredited

Thermal Arc Service
Agent or a qualified
electrician check the
Mains voltage.

No weld current is
available.Buzzer
sounds constantly.
Switch machine
OFF.

9 E82 error code displayed

Rated voltage selection
circuit abnormality.

The Primary supply

(input) voltage
fluctuates and is
not stable.

Have an accredited

Thermal Arc Service
Agent or a qualified
electrician check the
Mains voltage.

No weld current is
available. Buzzer
sounds constantly.
Switch machine
OFF then ON to
reset E82 error.