21
8
SMART Logic Switch
Manual slide switch mounted on the back panel selects for proper input voltage. If this slide is not set
to the position that matches the input voltage from the electrical source the Smart Logic circuit will
inhibit welding power source output. The digital meter will show primary input error code.
9
Gas Inlet
The Gas Inlet is a 5/8 18 UNF female gas fitting.
4.02 Weld Process Selection for ArcMaster 200AC/DC
Weld
Mode
Weld Process
Selection
STICK
HF
TIG
LIFT
TIG
Description
STD
Yes Yes Yes
2T operation in TIG Modes using remote
devices to control contactor & current.
SLOPE
No Yes Yes
4T operation in TIG Modes with crater fill
using a remote contactor device to
control sequence.
REPEAT
No Yes Yes
4T operation in TIG Modes with repeat
operation and crater fill using a remote
contactor device.
SPOT
No Yes No
2T operation spot welding in HF TIG using
a remote contactor device.
PULSE
ON/OFF
No
Yes
Yes
Pulse operation in TIG Modes.
Yes
Yes
Yes
Selects AC or DC weld current.
Contactor ON/OFF
Yes
No
Yes
Contactor operation in Stick Mode.
Operation
PANEL/REMOTE
Yes
Yes
Yes
Selects in Operation Panel Board or Remote.
Table 3 – Weld Process Selection verses Weld Mode for ArcMaster 200 ACDC