Section 2: introduction & description, 01 scope of manual, 02 general description – Tweco Max 300 w-TD-750 User Manual
Page 15: 03 specifications & design features, Section 2, Introduction & description

Manual 0-2557
9
INTRODUCTION & DESCRIPTION
SECTION 2:
INTRODUCTION &
DESCRIPTION
2.01 Scope of Manual
This manual contains descriptions, operating instructions
and maintenance procedures for the Liquid Cooled Maxi-
mizer 300 Torch and Torch Leads Extension Assemblies.
Service of this equipment is restricted to Thermal Dynam-
ics trained personnel; unqualified personnel are strictly
cautioned against attempting repairs or adjustments not
covered in this manual, at the risk of voiding the War-
ranty.
Read this manual thoroughly. A complete understand-
ing of the characteristics and capabilities of this equip-
ment will assure the dependable operation for which it
was designed.
2.02 General Description
NOTE
Refer to Section 2.05, Introduction To Plasma, for
a more detailed description on plasma theory.
The Liquid Cooled Maximizer 300 Torch is a liquid cooled
torch that provides cutting capacity of up to 2 inch (50.8
mm) at 140 amperes. In the torch, two torch leads pro-
vide plasma and secondary gas to the torch head. The
leads also provide the closed loop for the liquid coolant
flow from the Power Base Module. In the system the
Control Module torch connection is connected to the
Power Base Module by an umbilical cable.
Plasma torches are similar in design to the common au-
tomotive spark plug. They consist of negative and posi-
tive sections which are separated by a center insulator.
Inside the torch, the pilot arc is initiated in the gap be-
tween the negatively charged electrode and the positively
charged tip. Once the pilot arc has ionized the plasma
gas, the superheated column of gas flows through the
small orifice in the torch tip, which is focused on the metal
to be cut. The torch connects to a tool-free quick-connect
receptacle on the Control Module in the STAK PAK Sys-
tems or to the Arc Starter Box in TD-750 Systems.
2.03 Specifications & Design
Features
A. Maximizer 300 Torch
The following applies to the Liguid Cooled Maximizer
300 Torch only:
1. Maximizer 300 Torch Configuration
Maximizer 300 Machine Torch is supplied with a
Metal Rack and Pinion Mounting Assembly.
Machine Torch with
Metal Rack and Pinion Mounting Assembly
A-00659
Figure 2-1 Maximizer 300 Machine Torch
2. Torch Leads Length
NOTE
Lead lengths are from the Arc Starter Box to the
Torch Head Assembly on the TD-750 Systems.
10 ft (3.05 m)
15 ft (4.57 m)
20 ft (6.01 m)
25 ft (7.6 m)
Arc Starter Box extendable up to 100 ft (30.5
m) from the Power Base Module
3. Current Rating
140 Amps Max., DC, Straight Polarity
4. Duty Cycle
100%
5. Cutting Range
Most materials up to 2 inch (50.8 mm)
6. Pierce Rating
1 in (25.4 mm)
7. Transfer Distance
3/8 in (9.5 mm)
8. Torch Parts
Gas Distributor, Electrode, Tip, Shield Cup