13 rear panel parts replacement, 13 rear panel parts replacement -50 – Tweco 51 with SL100SV CutMaster User Manual
Page 114

SERVICE
5-50
Manual 0-4640
5
5.13 Rear Panel Parts Replacement
A. Filter/Regulator Assembly Replacement
WARNING
Disconnect the gas supply at the source and bleed down the system before performing this procedure.
1. Disconnect the gas input hose from the Filter/Regulator Assembly on the Rear Panel of the power supply.
2. Remove the four bolts securing the
Regulator Mounting Bracket to the Rear Panel.
3. Disconnect the black gas tube from the Filter/Regulator Assembly Adapter Fitting. Hold a wrench or similar tool against
the
locking ring on the Fitting and pull on the tube to release it.
4. Remove the nut securing the Filter/Regulator Assembly to the Regulator Mounting Bracket. Remove the Filter-Regulator
Assembly from the Mounting Bracket.
5. Install the replacement Filter/Regulator Assembly by reversing the steps above. When connecting the gas tube to the
Adapter Fitting, simply insert the hose into the fitting until fully seated and it will automatically lock.
B. Filter/Regulator Bracket Replacement
1. Remove the four bolts securing the
Regulator Bracket to the Rear Panel of the power supply.
2. Remove the nut securing the Filter/Regulator Assembly to the Regulator Bracket. Remove the Bracket from the Filter-
Regulator Assembly.
3. Install the replacement Bracket by reversing the above steps.
This completes the replacement procedures.