beautypg.com

T1 t2 t3, L1 l2 l3 – Tweco CutMaster 101 with SL100SV User Manual

Page 93

background image

Manual 0-4642

5-29

SERVICE

5

D. Main Input Power Test

WARNING

The following tests must be performed with the power supply connected to primary input power. There are extremely
dangerous voltage and power levels present inside this unit. Do not attempt to diagnose or repair without proper
training in power electronics measurement and troubleshooting techniques.

Reconnect power and observe proper start-up procedure. AC indicator on the Front Panel should be ON. If indicator is OFF there
is no voltage to the Power Supply or an overvoltage condition exists.

1. If AC indicator on Front Panel is OFF, check for proper AC input voltage between input cables on the Main Contactor.

Input voltage should be as shown in the following chart. If not, check for proper voltage at the main power source.

Nominal

Input Voltage

Contactor

Points

Voltage

Range

208/230VAC

L1, L2

187-253VAC

400VAC

L1, L3

360-440VAC

415VAC

L1, L3

370-460VAC

460VAC

L1, L3

414-506VAC

600VAC

L1, L3

517-632 VAC

Contactor Voltage Readings

Art # A-03194

Main Contactor

#13

#5

L1 L2 L3

T1

T2

T3

To E3

Connections to

Main PCB

#4

#12

To E1

To E2

Input Side

L1

L3

L2

Art # A-03212

L1 L2 L3 L4

T1

T2

T3

T4

#13

#12

#78

L1

L2

Input
Side

#5

#4

#3

#2

#1

Main Contactor

Main Input Contactor (460-Volt Three-Phase Input Power Shown) 208/230-Volt Main Input Contactor

2. Check for 28 VAC at J23-1 to J23-3 on the Main PC Board.

a. If greater than 30 VAC, input line power is too high.

b. If there is no AC power, check the fuse. If the fuse is okay, the auxiliary transformer is faulty. Replace the Main PC

Board.