SERVICE

5-22

Manual 0-4642

5

F. Gas flows; No arc in torch; AC

, GAS

, and DC

indicators ON; TEMP indicator

off

1. Faulty IGBT(s)

a. Measure between the following points on the IGBTs:

• IGBT A:

E4 to E10

E10 to E20

• IGBT B:

E23 to E27

E27 to E30

Voltage should be approximately 20 vdc before the start signal is active. If voltage measures greater than 100
vdc when the start signal is active, replace the respective IGBT(s).

Art # A-03659

INPUT
DIODE

E3

E7

E15

E10

E20

E4

J30

E33

E26

E27

E30

J31

E23

J25

IGBT A

IGBT B

J11