beautypg.com

Appendix 1: sequence of operation (block diagram), Patent information -17, Aappendix 1: sequence of operation (block diagram) – Tweco CutMaster 101 with SL100SV User Manual

Page 129

background image

Manual 0-4642

A-1

APPENDIX

A

APPENDIX 1: SEQUENCE OF OPERATION

(BLOCK DIAGRAM)

ACTION:

ON / OFF switch to ON

RESULT:

AC indicator ON.

Fan(s) ON.

GAS indicator ON

when input

pressure is adequate

for power supply operation.

Power circuit ready.

ACTION:

Protect eyes and activate torch.

RESULT:

Gas flows briefly, then stops.

Gas restarts.

DC indicator ON

Pilot arc established.

Art #A-03706

ACTION:

Unplug input

power cord or

open external

disconnect.

RESULT:

No power to system.

ACTION:

Connect work cable to workpiece.

Set output amperage.

RESULT:

System is ready

for operation.

ACTION:

RUN /

Rapid Auto Restart /

SET switch

to SET

RESULT:

Gas flows to set pressure.

ACTION:

RUN /

Rapid Auto Restart / SET

switch to RUN

(for most applications)

or to

Rapid Auto Restart

(for gouging, trimming,

or expanded metal

applications)

RESULT:

Gas flow stops.

ACTION:

Release torch trigger.

RESULT:

Main arc stops.

Gas flow stops after post - flow.

ACTION:

ON / OFF switch

to OFF

RESULT:

All indicators off.

Power supply fan(s) shuts off.

ACTION:

Close external

disconnect switch.

RESULT:

Power to system.

ACTION:

Torch moved within

transfer distance of workpiece.

RESULT:

Main arc transfers.

Pilot arc off.

PILOT ARC

ACTION:

Torch moved away from work (while

still activated).

RESULT:

Main arc stops.

Pilot arc automatically

restarts.