beautypg.com

05 main input and internal power problems, 05 main input and internal power problems -13 – Tweco CutMaster 101 with SL100SV User Manual

Page 77

background image

Manual 0-4642

5-13

SERVICE

5

5.05 Main Input and Internal Power Problems

A. Opening Power Supply Enclosure

The cover of the Power Supply must be removed for access to input power connections and test points.

WARNING

Disconnect primary power at the source before assembling or disassembling the Power Supply, torch parts, or torch
and leads assemblies.

1. Remove the upper screws securing the cover to the main assembly.
2. Loosen, but do not remove, the lower screws.

NOTE

There is a ground wire attached from the cover to the main body of the unit.

3. Carefully lift the cover off the unit, and remove the nut securing the ground wire to the side panel.

4. Re-install the cover by reversing the above steps.

Art # A-04510

Lower
screws

Upper screws

Ground wire

Lower
screws

Cover Removal